Application
LED screen for rental and stage events
Rental stock is bought once and used on every show, so the cabinet has to cover several pitches on one rigging plot and stay light enough for a two-person lift.
One cabinet, three pitches
A rental cabinet family that spans three pitches lets one stock line cover small stages and large ones, and lets a show upgrade resolution without buying new frames.
Rigging and weight
Cabinets are built to hang from a truss and to be struck in the dark. Weight per cabinet is the number a rental house plans around.
Spares and turnaround
Shows travel with spares, and modules are swapped in the venue. Front and rear access both matter on stage, depending on how the wall is flown.
What decides a rental cabinet, in order
Rental stock is decided by the truck and the crew before the picture.
- The crew sets the weight
- A 500 × 500 mm die-cast cabinet at 8 kg is a two-person lift and a one-person carry between cases; the 500 × 1000 mm version is 14.5 kg and takes two. Rental houses buy by cabinet weight and case count because that is what sets crew size and truck space.
- The deck sets the load
- Where the audience stands on the screen, Floor tiles are rated 2,000 kg/m² in the mask version and 1,200 kg/m² in GOB, with the walking surface as the service access — a damaged panel is a swap, not a floor lift.
- The venue sets the brightness
- Arenas and outdoor stages run 800 cd/m² and up on Flare and Flame; a wall flown in a dark room is dimmed rather than swapped for another product.
- The strike sets the frame
- Tool-free locks and one shared frame mean the same cabinet goes up as a flat wall, a curve or a half-arc, and comes down in the dark without tools.
| Room condition | What it rules in | What it rules out |
|---|---|---|
| Two-show weekend, four-person crew | 500 × 500 mm cabinet at 8 kg, tool-free locks | Cabinets that need three people or tools |
| Audience standing on the screen | Floor at 2,000 kg/m² (mask) or 1,200 kg/m² (GOB) | Unrated decks and floor lifts for one panel |
| Same stock, flat wall one night, curve the next | One frame, half-arc lock, five fixed angles | Separate curved product lines |
Boundary. We do not supply truss, rigging design or show engineering — the cabinet hangs from the structure the venue or the rigger provides.
How much does a rental LED cabinet weigh?
8 kg for 500 × 500 mm, 14.5 kg for 500 × 1000 mm.
What floor load does an LED floor need?
2,000 kg/m² in the mask version, 1,200 kg/m² in GOB.